Replace Air Filter
The access door of each Scalar i6000 control and expansion module has two air filters: one located at the top, and the other located at the bottom.
Many factors exist that contribute to the need to regularly service the air filters. For example, the total number of tape drives and the operating environment greatly affect the rate at which debris accumulates in the air filters.
With the maximum number of tape drives operating in a normal data center environment, you should check the filters every two years. If you see dust and debris on the inlet side of the filters, remove the filters and use water and a mild soap to clean them. The materials in the filters should last for the life of the product. However, if abnormal contamination occurs, you should replace them. To order filters, contact your service representative.
Use these instructions to remove either a top or bottom air filter.
Required tools: #1 Phillips screwdriver
-
Take the library offline.
-
On the operator panel, press Robotics Enabled to turn off power to the picker and return it to the home position. The power is on to all other components.
-
Open the access door. Aisle power is disabled.
-
Use the Phillips screwdriver to unscrew the two retaining thumbscrews. The screws remain attached to the retaining bar.
-
Remove the air filter.
-
Use water and a mild soap to clean the air filter.
-
Allow them to dry
Use these instructions to replace either a top or bottom air filter
Note: Make sure that the air filter is completely dry before placing it back in the access door.
Required tools: #1 Phillips screwdriver
-
Take the library offline.
-
On the operator panel, press Robotics Enabled to turn off power to the picker and return it to the home position. The power is on to all other components.
-
Open the access door. Aisle power is disabled.
-
Place the filter in the opening.
-
Place the retaining bar over the filter to hold it in place. Use the Phillips screwdriver to tighten the two retaining thumbscrews
-
Close the access door.
-
On the operator panel, press Robotics Enabled to enable the picker.
-
Bring the library online.